Customer type
1. Customer information: Jinhui Chemical is a chemical distributor. Among his customers, there is a thermal power plant. Because the desulfurizer foam cannot be solved, I found us on the Internet, hoping to give a solution
2. Sample information: desulfurization and defoaming agent
Desulfurizer incoming sample information |
|||
Appearance |
Colorless transparent liquid |
Viscosity |
thin |
Water solubility |
Good water solubility |
PH |
None |
Smell |
none |
3. Customer requirements: fast defoaming speed and long foam suppression time.
Principle and analysis of defoaming
1. Analysis of the cause of blistering
When the flue gas is washed by the limestone slurry in the absorption tower of the wet desulfurization system, a large amount of foam is produced.
2. The hazards of blistering
① Ash accumulation at the entrance of the bubble absorption tower.
②The liquid level in the tower is falsely high and the slurry overflows
3. Recommended for defoaming with defoamer
The power plant desulfurization defoamer is specially developed for the flue gas desulfurization slurry foaming system. It has transparency, good capacity, long-term defoaming and foam suppression performance, so as to control the liquid level in the tower, eliminate the false high liquid level caused by foam, and prevent The slurry overflows to alleviate the problem of fouling and clogging of the heat exchanger (GGH) caused by foam.
4. Product features
Tests should be carried out to determine applicability before use;
Stir gently before use;
Calculation of dosing amount: Generally, the addition amount of defoamer is 1~5‰, and the final usage amount is based on actual experiment. Under normal operation, the slurry amount is the standard. This product should be dosed in a one-off impact mode for the first time, and then added once every 24 hours. However, the actual dosage is determined by the composition of the foaming liquid, the amount of flue gas, the composition of coal, and the combustion process. Conditions, absorbents, and sulfur dioxide content. The user can finally determine the dosage according to the actual situation.
In the process of continuous addition, the pump can be used to calculate the addition, and it can be added at one time in the batch process.
Comparison of defoaming test
Sample No. |
Model |
Test Results |
A |
CQ-50 |
After use, it defoams quickly and suppresses foam (available) |
B |
CQ-51 |
When the addition amount is 0.1%, the transparency is average, with small particles of suspended matter; defoaming: 0:03:47; foam suppression: 0:03:50 (available) |
Both of these samples meet the requirements, depending on the customer's choice. |
Formula selection
Name of defoamer: desulfurization defoamer
The ingredients are as follows: (For details, please consult the fine chemical engineer of Nanhui Defoamer: 86 13428601010)